Estimate clean sintered wire mesh media pressure drop from measured permeability, or scale a reference measurement for the same filter element in the linear Darcy flow range.
For steady, single-phase Newtonian liquids in a confirmed Darcy flow range. Gas, slurry, fouled media and significant inertial resistance require other models or test data. This tool does not establish allowable differential pressure or a replacement threshold.
Enter your data, confirm the calculation conditions, then calculate.
Measured permeability: ΔP = μLQ / (kA). Superficial velocity v = Q/A.
Reference measurement: ΔP = ΔP₀ × (μ/μ₀) × (Q/Q₀).
SI calculation units: Q in m³/s, μ in Pa·s, L in m, A in m², k in m² and ΔP in Pa. 1 bar = 100,000 Pa; 1 mPa·s = 1 cP. Use viscosity at the operating temperature. If only kinematic viscosity ν is known, calculate dynamic viscosity from μ = ρν using consistent SI units.
The permeability method estimates media resistance only. Element support, internal bore, connections, housing and piping may add losses. The reference method retains the measurement boundary of the entered test; use an element-only measurement or independently verified viscous boundary.
For multiple identical parallel elements, total active area may be used only when flow is distributed evenly and each element has the same media properties. A micron rating does not uniquely determine permeability. Verify the estimate against a clean flow–pressure-drop curve and the permitted differential pressure for the actual assembly and flow direction.
No. Mesh weave, layer construction, compaction and flow direction affect permeability. Obtain measured permeability or a suitable clean-element test point.
The permeability method calculates media pressure drop. It excludes housing, support and connection losses. Reference scaling is valid only for the same boundary with confirmed linear viscous losses.
No. Gas compressibility, inertial flow, solids loading and non-Newtonian behavior need an appropriate model or measured curves.
No. Operating line pressure and allowable element differential pressure are different specifications. Use the approved assembly rating and project-specific cleaning or replacement criteria.
Filter area & face velocity calculator · General flow & pressure drop calculator · Pressure unit converter · Sintered mesh filter elements
ISO 4022:2018 — fluid permeability of permeable sintered metal materials describes permeability testing, including viscous and inertial coefficients. Darcy’s law equation formulation defines permeability, viscosity and superficial velocity. This calculator is a preliminary Darcy estimate, not an ISO test or certification.
For a project review, provide fluid and temperature, actual flow range, filtration requirement, element dimensions, clean pressure-drop data and allowable differential pressure. Discuss your filtration requirements.
Products
Resources
Contact us
Location:
Hi-Tech Industrial Zone, Hengshui,
Hebei, China, 053000
Contact:
+86 133 1308 7837
Email: info@alloyfilter.com