Measured Filter Flow & Pressure Drop Interpolation
Query a measured filter pressure-drop curve using piecewise linear interpolation between adjacent test points. Reverse mode queries flow at a measured-range pressure drop.
Use measurements from the same filter element, fluid, viscosity, temperature, condition and measurement boundaries, with actual flow at test conditions. Query within the measured endpoints; obtain additional measurements for a wider range. Report the result as interpolation, with separate evidence for Darcy parameters or a certified performance rating.
Interpolated result
Formula
For neighboring points (Q₁, Δp₁), (Q₂, Δp₂): f=(Q−Q₁)/(Q₂−Q₁); Δp=(1−f)Δp₁+fΔp₂. Reverse mode exchanges the flow and pressure axes. Only queries within the measured endpoints are accepted.
Frequently asked questions
Is linear interpolation a physical pressure-drop model?
No. It connects adjacent measurements with straight segments. Curvature between measurements may cause error; use more measured points and validate important operating points.
Can I mix a clean and a fouled filter curve?
No. Use data from comparable element conditions. Do not merge different filters or temperatures into one curve.
Why are non-monotonic pressure readings rejected?
This tool requires an unambiguous inverse query. Review test noise, units, pairings and conditions rather than having the tool silently change the measurements.
Can I query beyond the last test point?
No. Extrapolation is blocked. Obtain additional measurements or use a validated physical model.
Does this include piping and housing losses?
Only if those losses are included in the entered measurements. Preserve the same pressure-tap boundaries for every point and label the source accordingly.
Does the calculator average test results or uncertainty?
No. It uses each entered pair directly. No statistical confidence or standard-compliant overall test result is assigned.