Darcy Permeability Calculator

Back-calculate apparent directional permeability from measured liquid flow and media-only differential pressure.

Examples are not product data. Unit changes convert existing values.

Formula and assumptions

u = Q / A; k = μ × L × Q / (A × Δp); R = L / k

For steady, fully saturated, single-phase Newtonian liquid flow with constant viscosity in the linear Darcy regime. Use the gross exposed media area, not net opening area. Excludes inertial losses, compressible gases, gravity head, clogging, bypass, support/interface losses and housing losses. No material presets, rated capacity, service life or filtration efficiency are inferred. Example values are arithmetic examples, not product specifications.

Subtract independently measured fixture and support losses before entering Δp. A single point gives apparent permeability only. Confirm a linear flow–pressure relationship at multiple test points and report fluid, temperature and flow direction. Do not subtract an assumed loss. Very small Δp is sensitive to measurement uncertainty.

Frequently asked questions

Does this identify intrinsic permeability?

Only when the measurement and Darcy assumptions support it. A single result is labeled apparent permeability.

Can I enter total cartridge pressure loss?

Only if the media-only loss has been established. Housing, support and interface losses otherwise bias the result.

Can I use a dry-gas test?

This liquid model does not correct for gas compressibility or slip. Use a validated gas-specific method.

Is porosity enough to calculate permeability?

No. Permeability requires measured data or a validated structural model.

Model reference: COMSOL Darcy’s law equation formulation. Series equations follow from adding each layer’s Darcy pressure drop under the common-area assumptions above.

Required Filter Media Area from Allowed Darcy Pressure Drop

Estimate the effective flow-through area of a fully saturated porous medium carrying single-phase Newtonian liquid in the linear Darcy regime. Enter the independently measured directional permeability and the media-only pressure-drop allowance. This does not size housing, fittings, support layers or pipework.

Example results appear after calculation.

Formula and application

Darcy's law for the selected conditions is Δp = μLQ/(kA). Rearranging, A = μLQ/(kΔp), with Q in m³/s, viscosity μ in Pa·s, thickness L in m, permeability k in m² and pressure loss Δp in Pa. Minimum identical parallel pieces = ceil(required active area / usable area per piece). The estimated area uses the projected flow-through area of the medium, not its microscopic pore surface area.

Check the permeability in the relevant flow direction, pressure range, liquid and temperature. This linear model excludes inertial/Forchheimer effects, compressible fluids, contamination accumulation, non-Newtonian behavior, gravity contributions and unknown support/interface losses. Measured permeability or a validated test correlation is required; no universal permeability can be inferred from micron rating alone.

Worked example

For 1 m³/h liquid, dynamic viscosity 1 mPa·s, 1 mm thick media, permeability 1 µm² and 10 kPa media-only allowance: calculated required active area is approximately 0.027778 m². With 0.01 m² usable area per identical parallel piece, the initial geometric estimate is 3 pieces. Verify actual elements, flow distribution and total assembled-system pressure loss separately.

FAQ

Can I enter the maximum pressure drop of the entire filter system?

Not directly. Separate and reserve the relevant losses for housing, piping, fittings and supporting structures. Only the documented medium's allowance belongs in this model.

What if the media uses several sintered layers?

Do not automatically multiply permeability or active area. Use measured equivalent permeability in the relevant direction, or a validated series-resistance calculation for the actual layered structure.

Does the calculated area guarantee a certain flow rate?

No. It is a preliminary clean-medium estimate under Darcy conditions. Confirm with measured pressure-flow performance, manufacturing tolerances and operating fouling conditions.